跳转至

Accompanying Information Template

This template captures the controlled accompanying information set required for a released health software product under IEC 82304-1 clause 7. It provides the controlled product information that is delivered with, or made available to users of, the released software.

The accompanying information set is product-specific. Adapt the sections and tables to match the released product, but keep the controlled artifact set, revision state, and ownership clear.

Replace the example text below with product-specific content before approval.

1. Released Product Identification

Example:

  • Product name: ACME-GENERIC-SAMD
  • Product version or release: v1.0.0
  • Released-baseline reference: records/configuration/release_baseline_manifest.md
  • Manufacturer identification: ACME GmbH, Paradeplatz 8, 8001 Zurich, Switzerland
  • Unique product identifier or labeling reference: <UDI / labeling reference>

2. Instructions for Use (User-Facing)

Example structure for the IFU artifact set delivered with or made available to users:

Section Purpose Controlled Reference
Intended use and indications Describes intended medical purpose, intended users, and intended use environment records/mdf/intended_use.md
Contraindications, warnings, precautions States limits of use, residual risk warnings, and required user safeguards linked from risk file records/risk/risk_register.md
Operating instructions Step-by-step instructions for safe and effective product use product user documentation reference
Limitations and known issues Documents performance limits, unsupported configurations, and known anomalies relevant to safe use linked from records/verification_validation/vv_report.md
Support and incident reporting How to obtain support, report problems, or report incidents linked from records/feedback/ and records/incidents/

3. Technical Description

Example structure for the technical description delivered with or made available to qualified deployers, integrators, or operators:

Section Purpose Controlled Reference
Product overview Summary of product type, boundary, and architecture records/mdf/device_description.md
Operating environment requirements Required runtime environment, supported browsers, operating systems, network, and identity dependencies records/design/software_architecture_spec.md
Installation, configuration, and update model How the product is installed, configured, updated, or deployed records/configuration/release_plan.md, records/configuration/release_baseline_manifest.md
Interfaces and external dependencies API, identity, storage, audit, and supplier dependencies records/design/software_architecture_spec.md, supplier records
Security and data protection summary Security controls, audit logging, and data protection considerations relevant to safe operation records/risk/risk_register.md, security/architecture references
Maintenance and support expectations Expected maintenance, patching, support window, and end-of-support model sops/SOP-020-SoftwareLifecycleConfigurationAndReleaseManagement.md, records/configuration/

4. Languages and Localization

Example:

  • Languages provided with this released baseline: EN (primary), DE
  • Localization control note: only translations approved against the controlled source IFU and technical description are released
  • Translation evidence reference: records/configuration/ translation manifest or PR reference

5. Distribution and Availability

Example:

  • Delivery model: in-product help, downloadable PDF on the customer support portal, and API technical reference
  • Availability for regulators on request: yes
  • Distribution evidence reference: records/configuration/release_baseline_manifest.md

6. Change Control and Versioning

Example:

  • Accompanying information revision: R01
  • Linked product version: v1.0.0
  • Last reviewed for content currency: YYYY-MM-DD
  • Change-control rule: any change to intended use, indications, contraindications, warnings, precautions, supported environments, or end-of-support model triggers a controlled revision through the normal PR/signature/release flow

7. Approval Record

Example:

  • Accompanying information approved: yes
  • Approval date: YYYY-MM-DD
  • Linked approving PR: #123
  • Notes: approval covers the IFU and technical description set delivered with the listed product version