1. Purpose

Define how ACME GmbH governs the Quality Management System (QMS): ownership, review cadence, communication, document hierarchy, tooling governance, and the interfaces between top-level QMS policy, operational SOPs, and product-level records.

2. Scope

Applies to QMS governance activities, company-level role responsibilities, document hierarchy control, governance reviews, and the maintenance of QMS-wide reference baselines.

3. Inputs

  • Applicable standards and regulatory requirements
  • Organization context, interested-party needs, and customer requirements
  • QM-001 Quality Manual
  • Management review outputs and KPI trends
  • Audit, CAPA, complaint, PMS, supplier, and regulatory-scope inputs
  • Proposed QMS process, tooling, or documentation changes

4. Outputs

  • QMS governance review decisions and actions
  • Updated role and responsibility expectations
  • Approved QMS-wide reference baselines and governance records
  • Disseminated governance decisions and training-impact updates

5. Roles and Responsibilities

Role Responsibilities
Top Management Appoints the Management Representative within the defined governance model and retains ultimate responsibility for QMS effectiveness.
Management Representative Approves governance changes, confirms QMS adequacy/effectiveness, and acts for top management in the small-team model.
QA Lead Maintains governance cadence, the integrated quality/regulatory ownership baseline, and cross-document traceability completeness.
Engineering Lead / Usability Lead / Technical QMS Maintainer Maintain assigned procedures and evidence within their governed process area.
Auditor Independently verifies conformance and effectiveness of governed processes through audits.

6. Procedure

6.1 Governance Cadence

  1. Hold a QMS governance review at least quarterly.
  2. Review at minimum: organization context, interested-party needs, customer satisfaction signals, KPI trends, open CAPAs, audit findings, late training, supplier status, post-market signals, process risks/opportunities, and regulatory changes.
  3. Governance review outputs and decisions must be recorded and maintained as controlled quality records.
  4. Formal management review under SOP-004 uses governance-review outputs as an input for top-management confirmation of QMS suitability, adequacy, and effectiveness.

6.2 Responsibility and Communication Control

  1. Maintain the responsibility matrix for quality-affecting functions and role assignments in matrices/training_matrix.yml and related governance records.
  2. Disseminate governance decisions to impacted roles within five business days.
  3. Dissemination records must capture audience, channel, date, and any required follow-up.
  4. Maintain organizational knowledge needed to operate the QMS through controlled documents, training records, governance decisions, lessons learned, and approved repositories of record.

6.3 Quality Manual Interface

  1. QM-001 Quality Manual is the top-level orientation document for QMS purpose, scope, policy, objectives, and process interaction.
  2. SOP-005 governs how QM-001 and the related QMS baselines are maintained, approved, and communicated.
  3. Changes to QM-001 require impact review on downstream SOPs, traceability matrices, and training assignments before merge.

6.4 Regulatory Scope and Product Dossier Rules

  1. Jurisdiction baseline references are maintained in matrices/regulatory_market_scope.yml.
  2. Each product must maintain its own intended use, claims, classification rationale, and regulatory pathway in a product-specific dossier.
  3. Release is blocked for products missing approved regulatory dossier entries where required by the applicable process.

6.5 QMS Tooling Governance

  1. QMS digital tooling inventory is maintained in matrices/qms_tooling_inventory.yml.
  2. GitHub is the approved primary platform for QMS processes, including repositories, pull requests, issues, and workflows. Supporting signing and evidence components are defined and controlled in the QMS tooling inventory.
  3. Tooling changes require risk-based validation or revalidation evidence per SOP-006.

6.6 Supplier and Infrastructure Governance

  1. Supplier qualification, approved supplier maintenance, and re-evaluation are defined in SOP-010.
  2. Shared lifecycle infrastructure controls are defined in SOP-017; product-specific runtime controls are defined per product dossier.
  3. Governance review must consider supplier or infrastructure changes that could affect quality, compliance, or record integrity.

6.7 Change and Training Interface

  1. Any QMS process change must be assessed for impact on compliance obligations, product risk controls, existing controlled documents, and training mappings.
  2. Impacted QM or SOP revisions must be updated in the published controlled-document index and matrices/training_matrix.yml before merge.
  3. Governance changes that materially alter role expectations require training assignment review under SOP-011.

6.8 Effectiveness Monitoring

  1. QA Lead tracks:
  2. on-time management review completion
  3. QMS document update cycle time
  4. late training closure rate
  5. recurrence rate of systemic CAPAs
  6. Indicators are reviewed during governance review and fed into management review and CAPA when needed.

6.9 Standards Adoption Governance

  1. ACME adopts EVS-EN ISO 14971:2019+A11:2021 as the risk-management baseline standard for medical device software risk processes.
  2. ACME adopts EVS-EN 62366-1:2015+A1:2020 as the baseline standard for safety-related usability engineering.
  3. ACME adopts IEC 62304:2006+A1:2015 as the baseline standard for software lifecycle, maintenance, configuration management, and problem resolution.
  4. ACME adopts IEC 82304-1:2016 as the baseline standard for health software product safety, including product-level intended use, validation, identification, accompanying information, maintenance, and post-market interfaces.
  5. ACME adopts ISO/IEC 27001:2022, including ISO/IEC 27001:2022/Amd 1:2024, as the baseline standard for information security management across QMS repositories, product information, suppliers, operations, and supporting systems.
  6. ACME adopts ISO/IEC 42001:2023 as the baseline standard for AI management for AI components inside ACME medical-device software, including AI policy, AI lifecycle, AI risk and impact assessment, and complete Annex A control consideration through a Statement of Applicability.
  7. ACME adopts ISO 9001:2015, including ISO 9001:2015/Amd 1:2024, as the general quality-management baseline for organization context, customer focus, process performance, organizational knowledge, risks and opportunities, and continual improvement.
  8. Governance review verifies whether newly applicable standards, guidance, or changes to adopted standards affect the QMS baseline.
  9. Changes to these standards or their supporting processes must be reflected in the affected SOPs, WIs, and matrices.

6.10 GitHub Workflow Alignment Rule

  1. Controlled QMS changes follow a GitHub-native lifecycle: change context is established in a separate issue or directly in the pull request, then work proceeds through branch -> pull request -> required checks/approvals -> merge -> signature attestation -> immutable release evidence.
  2. Branch-only and PR-draft content may be used for collaboration, but it is not approved controlled state.
  3. The controlled repository baseline exists on main and, where applicable, on approved immutable release tags and release assets created from main.
  4. The signature mechanism is common across this upstream baseline and designated product/study record repositories.

7. Required Records

  • QMS governance review minutes and action log
  • Responsibility matrix and dissemination records
  • Regulatory scope register review record
  • QMS tooling validation or revalidation references
  • Product dossier governance decisions where applicable

8. Traceability

Standard Clause Control in this SOP Linked Artifact
ISO 13485:2016 4.1.4 Defines QMS process change impact control and governance follow-up. Change records, training matrix updates, published controlled-document index
ISO 13485:2016 4.1.6 Defines governance of QMS software applications and validation expectations. matrices/qms_tooling_inventory.yml, sops/SOP-006-SoftwareValidation.md
ISO 13485:2016 5.5 Defines responsibilities, authority, communication, and governance dissemination. Responsibility matrix, governance review minutes, dissemination records
ISO 9001:2015 4, 5.1, 6.1, 7.1.6 Defines organization context, interested-party/customer interfaces, process risks and opportunities, and organizational knowledge governance. matrices/iso_9001_gap_analysis.yml, governance review minutes, management review inputs
  • QM-001 Quality Manual
  • SOP-001 Document and Record Control
  • SOP-004 Management Review
  • SOP-006 Software Validation (QMS Tools)
  • SOP-010 Supplier and Purchasing Control
  • SOP-011 Competence, Training, and Awareness
  • SOP-012 Feedback and Complaint Handling
  • SOP-016 Quality Metrics and Data Analysis
  • SOP-017 Infrastructure and Maintenance Control
  • SOP-021 Information Security Management (ISO/IEC 27001:2022)
  • SOP-022 AI Management System (ISO/IEC 42001:2023)
  • SOP-018 Risk Management (ISO 14971:2019)
  • SOP-019 Usability Engineering (IEC 62366-1:2015)
  • SOP-020 Software Lifecycle, Configuration, and Release Management (IEC 62304:2006+A1:2015)

10. Revision History

Revision Revision Date Change Summary
R00 2026-03-01 Initial release (skeleton content).
R01 2026-03-01 Expanded to full operating procedure with ACME GmbH context and governance controls.
R02 2026-03-01 Added exact CH/EU/US regulatory reference baseline, product-specific intended use/infrastructure rules, GitHub-only QMS tooling governance, and supplier-model dependency handling.
R03 2026-03-02 Aligned related-process references to implemented SOP-006..SOP-017 and finalized supplier/infrastructure cross-links.
R04 2026-03-02 Added ISO 14971:2019 adoption and integrated risk governance linkage to SOP-018 and the risk matrix baseline.
R05 2026-03-02 Added IEC 62366-1:2015 adoption and usability engineering governance linkage to SOP-019 and the usability matrix baseline.
R06 2026-03-05 Added repository-of-record governance for product/study records, clarified IEC 62366 evidence location, and added explicit rule to keep SOP lifecycle wording aligned with implemented GitHub workflow.
R07 2026-03-06 Added IEC 62304:2006+A1:2015 adoption, linked lifecycle execution instructions, and required product-level lifecycle/release record references.
R08 2026-03-07 Normalized small-team accountability language to role owners and management representative responsibilities used in the controlled role matrix.
R09 2026-03-07 Renamed controlled lead roles to the simplified *_lead/auditor taxonomy and removed product-owner wording from governance responsibilities.
R10 2026-03-07 Added usability_lead to the controlled role taxonomy and clarified that usability ownership is distinct from regulatory oversight.
R11 2026-03-07 Clarified that only main and approved immutable releases are controlled baselines, and that the GitHub lifecycle may be initiated directly from PR-stated change context when no separate issue is used.
R12 2026-03-07 Removed overly specific signature-regulation terminology from the QMS workflow wording and used technology-neutral signature language.
R13 2026-03-08 Split the reader-facing Quality Manual into QM-001 and limited SOP-005 to governance, ownership, cadence, and control interfaces.
R14 2026-03-10 Updated DearAuditor Open QMS Baseline naming, licensing, and open-source governance references.
R15 2026-03-18 Removed top-table standards clause metadata; normative references remain in the Traceability section.
R16 2026-03-25 Reduced governance-review cadence to quarterly, added explicit top-management accountability and recordkeeping, refined tooling-governance wording, and required review of newly applicable standards.
R17 2026-03-27 Consolidated the standalone regulatory-lead governance role into the QA-lead ownership baseline and removed the redundant separate role reference.
R18 2026-04-23 Added IEC 82304-1:2016 as the adopted health software product-safety baseline standard and connected it to product-level lifecycle controls.
R19 2026-04-27 Added ISO/IEC 27001:2022 adoption and linked the dedicated ISMS procedure into the governance baseline.
R20 2026-04-27 Added ISO/IEC 42001:2023 adoption for AI components inside ACME medical-device software and linked the dedicated AIMS procedure into the governance baseline.
R21 2026-04-27 Renamed YAML metadata field effective_date to revision_date to align controlled-document metadata with the tag-based publication model. The effective date is derived from the published QMS release tag rather than from the document front matter.
R22 2026-05-04 Standardize standards citations to specific versions.
R23 2026-05-26 Added the ISO 9001 governance overlay for organization context, interested parties, customer satisfaction signals, process risks/opportunities, and organizational knowledge.